Isolation Transformerused to establish a new neutral-ground bond in order to correct common mode and other grounding problems. A transformer can provide conversion of a Delta system (3 wire) to a Wye connected (4 wire) system. A shielded isolation transformer provides excellent protection from all types of N-G disturbances (impulses, RMS voltage, and high frequency noise). It also protects against voltage transients and spikes while offering full rd galvanic isolation, traps 3 harmonic and triplen harmonics.
We hereby introduce ourselves as a manufacturer of dry type power transformers. We are established in this field since 2003. Our Dry Type Transformer adopt high quality low loss silicon sheet and arranged non-bobbin coil winding technology, and we apply vacuum pressure impregnating (VPI) process and solidify baking process to achieve insulation class H or C. Our transformers are widely used on any occasions where voltage is below 1000V and frequency below 400 Hz, and equipment’s which require voltage to step up or down.
Features
1) There are air flows between coil's layer to layer and between coil to core, resulting fast heat dissipation, and low temperature rise.
2) High grade iron core and winding can be wire or foil.
3) Small volume, light weight and good workmanship.
4) After vacuum pressure impregnating, the whole transformers and reactors are moisture proof and mildew proof. Insulation class H or C.
6) Lower audio noise.
7) Nomex based insulation system for foil winding transformers.
Type
1) Step up Isolation Transformer
2) Step down Isolation Transformer
Testing
Our all magnetics are tested as per routine test mentioned as per IS2026. We can carry out other type testing as per your need.
Applications of Isolation Transformers
This type is suitable in some computer network designs, CNC machines, etc.
Our products range is as under:
1) Single/3 phase Transformer, upto 300KVA, 50Hz - 400Hz.
2) Scott Connected (3phase - 2phase conversion)/ Open delta type (3phase--single phase conversion)
3) Input Chokes for A.C/D.C Drives, from 1hp to 750hp drives
4) Output Chokes for A.C/D.C Drives, from 1hp to 750hp drives
5) DC filter choke
6) Harmonic Filter Choke
7) Transformers for Plasma Welding Machines
8) Transformers with induction heating purpose.
Product Details:
Primary Voltage | 415 Volts |
Power (VA) | 75 KVA |
Cooling Type | Dry type/Air cooled |
Secondary Voltage | 415 Volts |
Product Details:
Frequency | 50Hz |
Phase | Three |
Brand | Arzoo Energy |
Cooling Type | Dry type/Air cooled, Oil Cooled |
Usage/Application | Educational, Residential, Industrial, Commercial |
Operating Temperature | 0-50 |
Transformers with primary (input) and secondary (output) windings separated from each other are known as isolation transformers. Under this construction, the input power and the output power are electrically separated by an dielectric insulation barrier.
Features:
· High Quality
· Affordable Prices
· Reliable
· Sturdy
· Highly efficient
· Adaptable
Additional Information:
Product Details:
Phase | Three Phase |
Power (VA) | 12 KVA |
Secondary Voltage | 415 Volts |
Primary Voltage | 415 Volts |
Cooling Type | Dry type/Air cooled |
Usage | Power |
Current | 16.9 AMP |
Frequency | 50 Hz |
Product Details:
Phase | Three Phase |
Power (VA) | 20 KVA |
Secondary Voltage | 415 Volts |
Primary Voltage | 415 Volts |
Cooling Type | Dry type/Air cooled |
Frequency | 50 hz |
Current | 28 amp |
Product Details:
Phase | Three Phase |
Power (VA) | 25 KVA |
Secondary Voltage | 415 Volts |
Primary Voltage | 415 Volts |
Cooling Type | Dry type/Air cooled |
Frequency | 50 hz |
Current | 35 amp |
Product Details:
Phase | Three Phase |
Power (VA) | 30 KVA |
Secondary Voltage | 415 Volts |
Primary Voltage | 415 Volts |
Cooling Type | Dry type/Air cooled |
Frequency | 50 hz |
Current | 42 amp |
Product Details:
Phase | Three Phase |
Power (VA) | 35 KVA |
Secondary Voltage | 415 Volts |
Primary Voltage | 415 Volts |
Cooling Type | Dry type/Air cooled |
Frequency | 50 hz |
Current | 49 amp |
Product Details:
Cooling Type | Air Cooled |
Current | 126 AMP |
Phase | Three Phase |
Power | 90 KVA |
Input Voltage | 415 Volts |
Output Voltage | 415 Volts |
Frequency | 50 Hz |
Product Details:
Phase | Three Phase |
Input Voltage | 415 Volts |
Cooling Type | Air Cooled |
Current | 112 AMP |
Power | 80 KVA |
Output Voltage | 415 Volts |
Frequency | 50 Hz |
Product Details:
Power (VA) | 15 KVA |
Secondary Voltage | 415 Volts |
Primary Voltage | 415 Volts |
Cooling Type | Dry type/Air cooled |
Phase | Three Phase |
Current | 21 AMP |
Frequency | 50 Hz |
Product Details:
Phase | Three Phase |
Power (VA) | 10 KVA |
Secondary Voltage | 415 Volts |
Primary Voltage | 415 Volts |
Cooling Type | Dry type/Air cooled |
Source | Electrical |
Current | 16.9 AMP |
Frequency | 50 Hz |
Product Details:
Power (VA) | 5 KVA |
Secondary Voltage | 415 Volts |
Primary Voltage | 415 Volts |
Cooling Type | Dry type/Air cooled |
Phase | Three Phase and Single Phase |
Current | 7 Amp |
Frequency | 50 Hz |
Backed by talented & skilled professionals and rich industry-experience, we are able to offer a wide range of Isolation Transformer that is widely used in various industrial applications. These products are rigorously examined against different parameters of quality to deliver the flawless range to our clients. The products offered by us are available in standard as well as customized specification as per the varied requirements of our clients. Apart from this, these are highly acclaimed among the clients for their several qualitative attributes such as durability and reliability.
Product Details:
Phase | Three Phase |
Power (VA) | 40 KVA |
Secondary Voltage | 415 Volts |
Primary Voltage | 415 Volts |
Cooling Type | Dry type/Air cooled |
Frequency | 50 hz |
Current | 55.6 amp |
Product Details:
Phase | Three Phase |
Power (VA) | 60 KVA |
Secondary Voltage | 415 Volts |
Primary Voltage | 415 Volts |
Cooling Type | Dry type/Air cooled |
Current | 83.5 amp |
Frequency | 50 Hz |
Product Details:
Phase | Three Phase |
Power (VA) | 150 KVA |
Secondary Voltage | 415 Volts |
Primary Voltage | 415 Volts |
Cooling Type | Dry type/Air cooled |
Current | 210 AMP |
Product Details:
Phase | Three Phase |
Power (VA) | 100 KVA |
Secondary Voltage | 415 Volts |
Primary Voltage | 415 Volts |
Cooling Type | Dry type/Air cooled |
Current | 140 AMP |
Product Details:
Phase | Single Phase |
Brand | Arzoo Energy |
Cooling Type | Oil Cooled, Dry Type/Air Cooled |
Frequency | 50Hz |
Usage/Application | Industrial, Residential, Educational, Commercial |
Operating Temperature | 0-50 |
Transformers with primary (input) and secondary (output) windings separated from each other are known as isolation transformers. Under this construction, the input power and the output power are electrically separated by an dielectric insulation barrier.
Features:
· High Quality
· Affordable Prices
· Reliable
· Sturdy
· Highly efficient
· Adaptable
Additional Information:
Product Details:
Cooling Type | Oil Cooled, Water Cooled, Dry type/Air cooled |
Product Details:
Phase | Three Phase |
Power (VA) | 50 KVA |
Secondary Voltage | 415 Volts |
Primary Voltage | 415 Volts |
Cooling Type | Dry type/Air cooled |
Output voltage | 415 volts |
Current | 69.5amp |